HPLC analysis
A bench-top HPLC with its own control and reporting software, built for small businesses and QC teams that want results the same day instead of waiting on an outside lab.
Used by universities, research labs, commercial testing labs and government departments worldwide.
NIST-traceable calibration · Formal quotes for universities, labs and government buyers
Start with a validated method kit, or ask us to develop a method for your compounds.
The CTS-300 took part in the NIST Laboratory Quality Assurance Program, which compared about 140 North American labs measuring the same certified reference material. Learn more →
Software
CTI LIMS imports CTS-300 results automatically, so nothing is retyped. Log samples, print barcodes, generate COAs and keep a full audit trail.
| System | |
|---|---|
| Pump | Reciprocating |
| Detector | UV/VIS |
| Injector | Rheodyne 7725i manual injector, or autosampler |
| Column compartment | Temperature-controlled |
| Software | CTI HPLC software included. CTI LIMS optional (licence agreement) |
| Calibration | NIST-traceable, certificate included |
| Pump performance | |
| Flow rate | 0.001–5 mL/min |
| Maximum pressure | 6,300 psi |
| Flow accuracy | ≤ ±1% |
| Flow precision | RSD < 0.1% |
| Qualitative repeatability | RSD ≤ 0.2% (naphthalene/methanol standards) |
| Quantitative repeatability | RSD ≤ 0.5% (naphthalene/methanol standards) |
| Detector performance | |
| Wavelength range | 180–680 nm |
| Spectral bandwidth | 8 nm |
| Wavelength accuracy | ±1 nm |
| Wavelength precision | < 0.1 nm |
| Noise | ≤ 0.25 × 10−5 AU |
| General | |
| Run time per sample | Depends on the method; 13.2 min for cannabinoid potency |
| Dimensions | 18 × 9 × 10.5 in (457 × 229 × 267 mm) |
| Weight | 45 lb (20.4 kg) |
| Power | 110 V or 220 V |
| Warranty | 1 year; UV lamp and column 90 days (warranty and returns) |
Compare your outside-lab cost per sample with running the CTS-300 yourself.
Open the ROI calculator →
HPLC analysis
A bench-top HPLC with its own control and reporting software, built for small businesses and QC teams that want results the same day instead of waiting on an outside lab.
Used by universities, research labs, commercial testing labs and government departments worldwide.
NIST-traceable calibration · Formal quotes for universities, labs and government buyers
Start with a validated method kit, or ask us to develop a method for your compounds.
The CTS-300 took part in the NIST Laboratory Quality Assurance Program, which compared about 140 North American labs measuring the same certified reference material. Learn more →
Software
CTI LIMS imports CTS-300 results automatically, so nothing is retyped. Log samples, print barcodes, generate COAs and keep a full audit trail.
| System | |
|---|---|
| Pump | Reciprocating |
| Detector | UV/VIS |
| Injector | Rheodyne 7725i manual injector, or autosampler |
| Column compartment | Temperature-controlled |
| Software | CTI HPLC software included. CTI LIMS optional (licence agreement) |
| Calibration | NIST-traceable, certificate included |
| Pump performance | |
| Flow rate | 0.001–5 mL/min |
| Maximum pressure | 6,300 psi |
| Flow accuracy | ≤ ±1% |
| Flow precision | RSD < 0.1% |
| Qualitative repeatability | RSD ≤ 0.2% (naphthalene/methanol standards) |
| Quantitative repeatability | RSD ≤ 0.5% (naphthalene/methanol standards) |
| Detector performance | |
| Wavelength range | 180–680 nm |
| Spectral bandwidth | 8 nm |
| Wavelength accuracy | ±1 nm |
| Wavelength precision | < 0.1 nm |
| Noise | ≤ 0.25 × 10−5 AU |
| General | |
| Run time per sample | Depends on the method; 13.2 min for cannabinoid potency |
| Dimensions | 18 × 9 × 10.5 in (457 × 229 × 267 mm) |
| Weight | 45 lb (20.4 kg) |
| Power | 110 V or 220 V |
| Warranty | 1 year; UV lamp and column 90 days (warranty and returns) |
Compare your outside-lab cost per sample with running the CTS-300 yourself.
Open the ROI calculator →